--- title: PowerRoute CNC Router Firmware Index (CNCU local) source_url: https://cncu.co.za/PowerRoute-CNC-Router/Firmwares/ fetched_at: 2026-08-13T11:27:00Z category: drivers pass: cncu-local-powerroute-firmware-batch + cncu-local-powerroute-deepen product: PowerRoute CNC Router (Syntec 11MA / 21-series Mill controller) --- # PowerRoute CNC Router — Firmware Index Inventory of **Syntec controller firmware / absolute-backup packages** and the **Syntec CNC upgrade ZIP** from the local cncu.co.za mirror under `T:\U\C\PowerRoute-CNC-Router\`, mapped to live `https://cncu.co.za/...` URLs. English prose only. **No pricing.** Firmware binaries themselves are **not** copied into this KB (pointer + URL only). ## What this firmware is PowerRoute industrial CNC routers in this tree use a **Syntec** mill controller (labels seen: **11MA / 11A**, **21-series Mill**, **Windows CE 7 ARM**). Assets fall into two groups: 1. **Syntec CNC Upgrade Packages** — full controller software image ZIP (`21AMillCE7_ARM_10.116.24T.zip`, Mill CE7 ARM build **10.116.24T**). Prefer the **newest matching controller family / version** when support directs an update (**newer wins** by version string, e.g. **10.116.24T** over older 10.116.x). 2. **Firmwares\Syntec 11MA Absolute Backup** — machine-serial absolute backups dated **2023-05-19** for unit **M1F1449** (MB = main/parameter disk tree; SB = OpenInstaller side / system image config). These are **restore points for that machine**, not a general “flash this on every PowerRoute.” Wrong-machine restore risk — only when support directs. Support WhatsApp +27 60 600 7000. OpenInstaller metadata on the SB package: `Syntec Cnc` version **Mill7_10.116.0N**, platform **WindowsCE_7**, cpu **ARM**, model **11A**. ## English manuals (pointers + KB copies) | Guide | Local path | Online URL | Verified | KB action | | --- | --- | --- | --- | --- | | Mill Operation Manual.pdf (~4.19 MB) — **English handbook** (21 Series Mill Controller Operation Manual; TOC in English) | `T:\U\C\PowerRoute-CNC-Router\Mill Operation Manual.pdf` | https://cncu.co.za/PowerRoute-CNC-Router/Mill%20Operation%20Manual.pdf | HTTP 200 | **Copied** to `sources/manuals/powerroute/Mill-Operation-Manual.pdf` | | Mill Programming Manual.pdf (~1.34 MB) — English G-code / programming companion | `T:\U\C\PowerRoute-CNC-Router\Mill Programming Manual.pdf` | https://cncu.co.za/PowerRoute-CNC-Router/Mill%20Programming%20Manual.pdf | HTTP 200 | **Copied** to `sources/manuals/powerroute/Mill-Programming-Manual.pdf` | Note: PDF catalog `Lang` tag is `zh-TW`, but body/title/TOC observed via foldersweb HTML extracts are **English** Syntec mill manuals (kept under English-only rule). ## Primary firmware / upgrade packages ### A. Syntec CNC Upgrade Packages Base local dir: `T:\U\C\PowerRoute-CNC-Router\Syntec CNC Upgrade Packages\` Base URL: `https://cncu.co.za/PowerRoute-CNC-Router/Syntec%20CNC%20Upgrade%20Packages/` | Package | Family / version | Payload note | Local path | Online URL | Size (approx) | Verified | | --- | --- | --- | --- | --- | --- | --- | | 21AMillCE7_ARM_10.116.24T.zip | Syntec 21A Mill CE7 ARM **10.116.24T** | Controller upgrade image ZIP (no extracted folder twin in mirror) | `...\Syntec CNC Upgrade Packages\21AMillCE7_ARM_10.116.24T.zip` | https://cncu.co.za/PowerRoute-CNC-Router/Syntec%20CNC%20Upgrade%20Packages/21AMillCE7_ARM_10.116.24T.zip | ~8.39 MB | ZIP HTTP 200; folder twin path **404** (ZIP-only) | Folder index https://cncu.co.za/PowerRoute-CNC-Router/Syntec%20CNC%20Upgrade%20Packages/ — **HTTP 200**. ### B. Syntec 11MA Absolute Backup (machine M1F1449, 2023-05-19) Base local dir: `T:\U\C\PowerRoute-CNC-Router\Firmwares\Syntec 11MA Absolute Backup\` Base URL: `https://cncu.co.za/PowerRoute-CNC-Router/Firmwares/Syntec%2011MA%20Absolute%20Backup/` | Package | Role | Payload note | Local path | Online URL | Size (approx) | Verified | | --- | --- | --- | --- | --- | --- | --- | | M1F1449_20230519_MB_CCA35630 | Absolute backup **MB** (main disk tree) | ZIP + extracted tree: AlarmMacro, HistoryAlarm, Ladder, Macro, OCRes, OPLog, Parameter, ParameterExt, Registry (`param.dat`, `Param.txt`, `Registry.dat`, ladder/XML, etc.). System Version string in Param.txt: **1011600014** | `...\M1F1449_20230519_MB_CCA35630\` and `.zip` | https://cncu.co.za/PowerRoute-CNC-Router/Firmwares/Syntec%2011MA%20Absolute%20Backup/M1F1449_20230519_MB_CCA35630/ ; ZIP https://cncu.co.za/PowerRoute-CNC-Router/Firmwares/Syntec%2011MA%20Absolute%20Backup/M1F1449_20230519_MB_CCA35630.zip | folder present / ZIP ~2.29 MB | folder HTTP 200; ZIP HTTP 200 | | M1F1449_20230519_SB_C7F3F83A | Absolute backup **SB** (OpenInstaller side) | ZIP + `OpenInstallerConfigurationFile.xml` (Mill7_10.116.0N / 11A / WinCE7 ARM) | `...\M1F1449_20230519_SB_C7F3F83A\` and `.zip` | https://cncu.co.za/PowerRoute-CNC-Router/Firmwares/Syntec%2011MA%20Absolute%20Backup/M1F1449_20230519_SB_C7F3F83A.zip (folder under same base) | ZIP ~5.73 MB | ZIP HTTP 200 | Parent Firmwares index https://cncu.co.za/PowerRoute-CNC-Router/Firmwares/ — **HTTP 200**. Absolute Backup folder — **HTTP 200**. **Firmware / backup package entries documented: 3** (1 upgrade ZIP + 2 absolute-backup ZIP/folder pairs). ## URL verification notes (`fetched_at` 2026-08-12T22:23:00Z) **Confirmed HTTP 200 (HEAD):** - https://cncu.co.za/PowerRoute-CNC-Router/ - https://cncu.co.za/PowerRoute-CNC-Router/Firmwares/ - https://cncu.co.za/PowerRoute-CNC-Router/Firmwares/Syntec%2011MA%20Absolute%20Backup/ - https://cncu.co.za/PowerRoute-CNC-Router/Firmwares/Syntec%2011MA%20Absolute%20Backup/M1F1449_20230519_MB_CCA35630/ - https://cncu.co.za/PowerRoute-CNC-Router/Firmwares/Syntec%2011MA%20Absolute%20Backup/M1F1449_20230519_MB_CCA35630.zip - https://cncu.co.za/PowerRoute-CNC-Router/Firmwares/Syntec%2011MA%20Absolute%20Backup/M1F1449_20230519_SB_C7F3F83A.zip - https://cncu.co.za/PowerRoute-CNC-Router/Syntec%20CNC%20Upgrade%20Packages/ - https://cncu.co.za/PowerRoute-CNC-Router/Syntec%20CNC%20Upgrade%20Packages/21AMillCE7_ARM_10.116.24T.zip - https://cncu.co.za/PowerRoute-CNC-Router/Mill%20Operation%20Manual.pdf - https://cncu.co.za/PowerRoute-CNC-Router/Mill%20Programming%20Manual.pdf **Soft-fail / 404 (probes):** - https://cncu.co.za/PowerRoute-CNC-Router/Syntec%20CNC%20Upgrade%20Packages/21AMillCE7_ARM_10.116.24T/ — **404** (upgrade is ZIP-only; no extracted folder on live site) - https://cncu.co.za/PowerRoute-CNC-Router/Firmwares/Syntec%2011MA%20Absolute%20Backup/MISSING.zip — **404** (sanity probe) - https://cncu.co.za/PowerRoute-CNC-Router/CNC-Machining-Handbook.pdf — **404** (EasyRoute handbook path; not a PowerRoute file) ## Related English handbook + manuals (this batch) | Item | Local | Online | KB action | | --- | --- | --- | --- | | Mill Operation Manual.pdf (~4.19 MB) | product root | HTTP 200 | **Copied** → `sources/manuals/powerroute/Mill-Operation-Manual.pdf` | | Mill Programming Manual.pdf (~1.34 MB) | product root | HTTP 200 | **Copied** → `sources/manuals/powerroute/Mill-Programming-Manual.pdf` | No further English PDF/DOC books in this product folder (only the two mill manuals). Remaining English set (servo settings + _COM XML + OpenInstaller config) copied in the deepen pass below. ## Scope Read-only from `T:\U\C`. Writes only under `T:\V`. Did not crawl buythis or YouTube. One product line: **PowerRoute-CNC-Router** (did not fall back to RAYCUT — enough firmware present). ## Deepen pass (2026-08-13T11:27:00Z / 13:27 SAST) No **new firmware packages** (still **3**: upgrade ZIP `21AMillCE7_ARM_10.116.24T` + 2 Syntec 11MA absolute-backup ZIP/folder pairs for M1F1449). Binaries remain URL-only. Remaining English set copied under `sources/manuals/powerroute/` (see `drivers/powerroute-software-notes.md`): | Item | KB action | Online | | --- | --- | --- | | SBM AL301C AC Servo Driver Z-Axis Settings.txt | **Copied** to `manuals/powerroute/SBM-AL301C-AC-Servo-Driver-Z-Axis-Settings.txt` | HTTP 200 (missed in prior batch) | | AlarmMacro_COM.xml / AlarmPLC_COM.xml / ParamExt_COM.xml / ParamExt_RBit_COM.xml | **Copied** to `manuals/powerroute/components/` (English `_COM` only) | AlarmMacro_COM + ParamExt_COM HTTP 200 | | ConfigInfo.xml / DipoleSettings.xml | **Copied** to `manuals/powerroute/components/` | ConfigInfo HTTP 200 | | OpenInstallerConfigurationFile.xml | **Copied** to `manuals/powerroute/software/` | HTTP 200 | Re-verified this pass (HEAD HTTP 200): product root, both mill PDFs, SBM AL301C txt, Firmwares AlarmMacro_COM.xml, ParamExt_COM.xml, ConfigInfo.xml, OpenInstaller XML, upgrade ZIP `21AMillCE7_ARM_10.116.24T.zip`. **Still 404:** `.../Syntec%20CNC%20Upgrade%20Packages/21AMillCE7_ARM_10.116.24T/` (ZIP-only); `.../CNC-Machining-Handbook.pdf` (EasyRoute handbook; not a PowerRoute file). `Param.txt` exists online **200** but titles are Traditional Chinese -- **skipped**. Skipped: CHS/CHT XML, Chinese-comment macros O7913/T0000, firmware binaries / OPLog / param.dat / Registry.dat / cnc.lad, foldersweb HTML page-splits and thumbs, Histalm machine logs.